Technical Documentation
How the three pillars of a plant connect to iGromi: assets (PLCs, sensors, cameras), systems (protocols, networks, ERP) and the people who operate and decide. Step-by-step guides for integrators and maintenance teams.
Assets: machines, sensors and cameras
How the Edge and the Bridge read the PLCs, sensors, energy meters and cameras the plant already has, always read-only.
- Basic iGromi Bridge InstallationInstalling the iGromi Bridge in a cabinet: 35 mm DIN rail, 24V DC supply, WiFi or Ethernet link and pairing the gateway with your iGromi OS account.
- Connecting the Bridge to PLCs (Siemens, Allen-Bradley)Read tags from Siemens S7 and Allen-Bradley CompactLogix PLCs with the iGromi Bridge over Ethernet or serial, without stopping the machine or editing the Ladder.
- Integrating Existing Analog SensorsIntegrate existing 4-20mA and 0-10V analog sensors (load cells, pressure, level) into the iGromi Bridge in parallel, with no rewiring or replacement.
- Installing Production SensorsHow to wire 24V photoelectric, inductive or limit-switch sensors to the iGromi Bridge digital inputs to count production cycles and compute OEE automatically.
- AI Vision on Your Existing CamerasHow iGromi applies AI vision to the cameras a plant already has: counting at the Edge, per-plant training and what vision does not promise.
- Energy Monitoring (Modbus Analyzers)Connect per-machine Modbus power analyzers to iGromi OS to measure real kWh per cycle, allocate energy cost and detect early mechanical degradation.
- PT100 Temperature ProbesWiring 2-, 3- or 4-wire PT100 probes to the iGromi Bridge for ±0.1 °C process temperature measurement without an intermediate transmitter.
Systems: protocols, networks and integration
Industrial protocols, MQTT Sparkplug B, network segmentation and custom dashboards on top of connected data.
- Supported Industrial ProtocolsIndustrial protocols iGromi OS and its Edge nodes use to read plant data: OPC-UA, Modbus TCP and RTU, S7, EtherNet/IP, MQTT and more.
- MQTT Sparkplug B ConfigurationConfiguring MQTT Sparkplug B on iGromi OS: TLS broker on 8883, spBv1.0 topic hierarchy, NBIRTH/NDATA/NDEATH messages and detection of dropped Edge nodes.
- Purdue Model Firewall PoliciesFirewall rules per Purdue model level to deploy iGromi OS: the Bridge in the industrial DMZ, outbound-only traffic on 443/8883 and zero inbound ports.
- Building Dashboards with Node-REDStep-by-step guide to building Node-RED dashboards on iGromi OS: enable the module, read Unified Namespace tags and publish your own calculated KPIs.
People: operators and managers
First steps and alerts that reach whoever decides. AI notifies and proposes; a person approves.
- Getting Started with iGromi OSFirst login to iGromi OS: change the temporary password, enable 2FA, build the Plant > Line > Machine tree and link the first Bridge tag to the dashboard.
- Configuring Maintenance AlertsHow to set up maintenance alerts in iGromi OS: thresholds, trends and usage hours so you act before the failure instead of reacting to it.
Four rules that hold across all the documentation
AI reads, proposes and cites
Every @igromi answer carries its source: the sensor, the work order or the document.
A person decides
No alert or helper acts on the plant on its own.
The Edge is read-only
It reads PLCs, sensors and cameras; it never writes or changes setpoints.
No inbound ports
Every connection is outbound from the plant, encrypted.
API and integrations
Documentation for developers and systems integrators.
Safe industrial AI, starting free from the app.
The app gathers what your team knows: each trade with its helpers, and @igromi answers citing the source. AI reads, proposes and cites; a person decides. When you add systems and equipment, the Edge reads PLCs in read-only mode.
- AssetsPLCs, sensors, cameras, GPS
- SystemsSAP, ERP, MES, SCADA, spreadsheets
- PeopleOperators and managers: judgment and fixes
No credit card. Your data stays yours.